Vous êtes ici
Why do you need to control traces in Chlorine production?
At the different steps of the chlorine alkali process, some gas components can be found at trace level.Their concentrations can fluctuate over time and are depending on process parameters.
Species like O2, CO2, H2O are tracked in the chlorine gas matrix to insure the efficiency of the production process, and H2 is measured to avoid the explosion of the installation.
The ProCeas® Multigas Analyzer provides continuous measurement of H₂, O₂, CO₂ and H₂O in chlorine production, giving operators real time access to critical process information. Based on Optical Feedback Cavity Enhanced Absorption Spectroscopy (OFCEAS®), it measures H₂ down to ppm level with high linearity and no zero drift.
Unlike conventional technologies that require a significant delay after process start-up, ProCeas® provides real time H₂ readings, enabling earlier detection of concentration changes and more responsive process control. Hydrogen monitoring is critical for process safety in chlorine production (risk of explosion), while O₂, CO₂ and H₂O provide valuable insights into process conditions, equipment performance and gas quality.
Fast, reliable measurements help detect process deviations early, optimize process control and maintain safe operation. ProCeas® can monitor these gases individually or combine multiple measurements in one analyzer, providing flexibility to match specific process requirements. Its long-term stability and low maintenance make it particularly suited for continuous trace gas monitoring in demanding chlorine applications.
Technologies
Optical Feedback Cavity Enhanced Absorption Spectroscopy
The ProCeas® is an enhanced TDL analyzer. It uses the patented OFCEAS technique, based on extractive absorption spectroscopy.
This laser based technology is able to measure directly gases down to ppb levels of concentration, with an unforeseen quality of measurement in terms of accuracy and repeatability.
OFCEAS is also the only laser technique to measure directly hydrogen down to 3ppm, giving a real time measurement of H2 at startup with up to 10 measures per second.
Unique sampling system
ProCeas® is combined with a specific sampling system using only components compatible with the aggressive chlorine gas. Using no stainless-steel tubes and no pump. But composed of tubbing and connections in PVDF and PFA. Our long-term experience in the industry allowed us to optimize our sampling to measure in dry and wet chlorine.
Self-calibration
ProCeas® has an integrated self-calibration of the measurement system, featuring no zero and span drift over time. ProCeas® is able to analyze a large range of gases with limited maintenance costs.
Key features
Installation





Analytical specifications
Proceas® gas analyzer in Chlorine
Is a complete pre-calibrated single or multicomponent (H2, O2, H2O, CO2, etc.) laser infrared spectrometer for measurement of process gases.
| ANALYTICAL SPECIFICATIONS | ||
|---|---|---|
| Impurities | Rangea | LODb |
| H2 (ppm) | 0-5 000 | 10 |
| O2 (%vol) | 0-5 | 0.05 |
| CO2 (%vol) | 0-5 | 10 |
| H2O (ppm) | 0-1000 | 0.03 |
a adjustable range on request